HeatpumpIR library + sensors example to send IR commands to heatpumps
This commit is contained in:
@@ -0,0 +1,42 @@
|
||||
/*
|
||||
Carrier 42NQV035G / 38NYV035H2 heatpump control (remote control P/N WH-L05SE)
|
||||
*/
|
||||
#ifndef CarrierHeatpumpIR_h
|
||||
#define CarrierHeatpumpIR_h
|
||||
|
||||
#include <HeatpumpIR.h>
|
||||
|
||||
// Carrier (42NQV035G / 38NYV035H2) timing constants (remote control P/N WH-L05SE)
|
||||
#define CARRIER_AIRCON1_HDR_MARK 4320
|
||||
#define CARRIER_AIRCON1_HDR_SPACE 4350
|
||||
#define CARRIER_AIRCON1_BIT_MARK 500
|
||||
#define CARRIER_AIRCON1_ONE_SPACE 1650
|
||||
#define CARRIER_AIRCON1_ZERO_SPACE 550
|
||||
#define CARRIER_AIRCON1_MSG_SPACE 7400
|
||||
|
||||
// Carrier codes
|
||||
#define CARRIER_AIRCON1_MODE_AUTO 0x00 // Operating mode
|
||||
#define CARRIER_AIRCON1_MODE_HEAT 0xC0
|
||||
#define CARRIER_AIRCON1_MODE_COOL 0x80
|
||||
#define CARRIER_AIRCON1_MODE_DRY 0x40
|
||||
#define CARRIER_AIRCON1_MODE_FAN 0x20
|
||||
#define CARRIER_AIRCON1_MODE_OFF 0xE0 // Power OFF
|
||||
#define CARRIER_AIRCON1_FAN_AUTO 0x00 // Fan speed
|
||||
#define CARRIER_AIRCON1_FAN1 0x02
|
||||
#define CARRIER_AIRCON1_FAN2 0x06
|
||||
#define CARRIER_AIRCON1_FAN3 0x01
|
||||
#define CARRIER_AIRCON1_FAN4 0x05
|
||||
#define CARRIER_AIRCON1_FAN5 0x03
|
||||
|
||||
|
||||
class CarrierHeatpumpIR : public HeatpumpIR
|
||||
{
|
||||
public:
|
||||
CarrierHeatpumpIR();
|
||||
void send(IRSender& IR, byte powerModeCmd, byte operatingModeCmd, byte fanSpeedCmd, byte temperatureCmd, byte swingVCmd, byte swingHCmd);
|
||||
|
||||
private:
|
||||
void sendCarrier(IRSender& IR, byte operatingMode, byte fanSpeed, byte temperature);
|
||||
};
|
||||
|
||||
#endif
|
||||