HeatpumpIR library + sensors example to send IR commands to heatpumps
This commit is contained in:
@@ -0,0 +1,73 @@
|
||||
/*
|
||||
Hisense AQV12PSBN / AQV09ASA heatpump control (remote control P/N zzz)
|
||||
*/
|
||||
#ifndef HisenseHeatpumpIR_h
|
||||
#define HisenseHeatpumpIR_h
|
||||
|
||||
#include <HeatpumpIR.h>
|
||||
|
||||
|
||||
// Hisense timing constants
|
||||
#define HISENSE_AIRCON1_HDR_MARK 9060
|
||||
#define HISENSE_AIRCON1_HDR_SPACE 4550
|
||||
#define HISENSE_AIRCON1_BIT_MARK 520
|
||||
#define HISENSE_AIRCON1_ONE_SPACE 1700
|
||||
#define HISENSE_AIRCON1_ZERO_SPACE 630
|
||||
#define HISENSE_AIRCON1_MSG_SPACE 8140
|
||||
|
||||
// Power state
|
||||
#define HISENSE_AIRCON1_POWER_OFF 0x04 //**
|
||||
#define HISENSE_AIRCON1_POWER_ON 0x00 //**
|
||||
|
||||
// Operating modes
|
||||
// Hisense codes
|
||||
#define HISENSE_AIRCON1_MODE_AUTO 0x04 // Not available 0x00
|
||||
#define HISENSE_AIRCON1_MODE_HEAT 0x00
|
||||
#define HISENSE_AIRCON1_MODE_COOL 0x02
|
||||
#define HISENSE_AIRCON1_MODE_DRY 0x03
|
||||
#define HISENSE_AIRCON1_MODE_FAN 0x04
|
||||
#define HISENSE_AIRCON1_MODE_MAINT 0x04 // Power OFF
|
||||
|
||||
// Fan speeds. Note that some heatpumps have less than 5 fan speeds
|
||||
|
||||
#define HISENSE_AIRCON1_FAN_AUTO 0x00 // Fan speed
|
||||
#define HISENSE_AIRCON1_FAN1 0x03 // * low
|
||||
#define HISENSE_AIRCON1_FAN2 0x02 // * med
|
||||
#define HISENSE_AIRCON1_FAN3 0x01 // * high
|
||||
#define HISENSE_AIRCON1_FAN4 0x01 // * high Not available
|
||||
#define HISENSE_AIRCON1_FAN5 0x01 // * high Not available
|
||||
|
||||
// Not available in this model.
|
||||
// Vertical air directions. Note that these cannot be set on all heat pumps
|
||||
#define HISENSE_VDIR_AUTO 0
|
||||
#define HISENSE_VDIR_MANUAL 0
|
||||
#define HISENSE_VDIR_SWING 0
|
||||
#define HISENSE_VDIR_UP 0
|
||||
#define HISENSE_VDIR_MUP 0
|
||||
#define HISENSE_VDIR_MIDDLE 0
|
||||
#define HISENSE_VDIR_MDOWN 0
|
||||
#define HISENSE_VDIR_DOWN 0
|
||||
|
||||
// Not available in this model.
|
||||
// Horizontal air directions. Note that these cannot be set on all heat pumps
|
||||
#define HISENSE_HDIR_AUTO 0
|
||||
#define HISENSE_HDIR_MANUAL 0
|
||||
#define HISENSE_HDIR_SWING 0
|
||||
#define HISENSE_HDIR_MIDDLE 0
|
||||
#define HISENSE_HDIR_LEFT 0
|
||||
#define HISENSE_HDIR_MLEFT 0
|
||||
#define HISENSE_HDIR_MRIGHT 0
|
||||
#define HISENSE_HDIR_RIGHT 0
|
||||
|
||||
|
||||
class HisenseHeatpumpIR : public HeatpumpIR
|
||||
{
|
||||
public:
|
||||
HisenseHeatpumpIR();
|
||||
void send(IRSender& IR, byte powerModeCmd, byte operatingModeCmd, byte fanSpeedCmd, byte temperatureCmd, byte swingVCmd, byte swingHCmd);
|
||||
|
||||
private:
|
||||
void sendHisense(IRSender& IR, byte powerMode, byte operatingMode, byte fanSpeed, byte temperature, byte swingV, byte swingH);
|
||||
};
|
||||
|
||||
#endif
|
||||
Reference in New Issue
Block a user