HeatpumpIR library + sensors example to send IR commands to heatpumps
This commit is contained in:
@@ -0,0 +1,92 @@
|
||||
#include <MideaHeatpumpIR.h> // https://github.com/ToniA/arduino-heatpumpir
|
||||
#include <Button.h> // http://playground.arduino.cc/Code/Button
|
||||
|
||||
/*
|
||||
|
||||
This is a project I did for my my friend's summer cottage. He has an alarm system
|
||||
with some extra relays which can be controlled via GSM SMS messages. With two relays
|
||||
we can have four heatpump states:
|
||||
* relay 1 OFF and relay 2 in any state: heatpump OFF
|
||||
* relay 1 ON and relay 2 OFF: heatpump ON, normal heating state
|
||||
* relay 1 ON and relay 2 ON: heatpump ON, maintenance heating (FP mode on Midea's remote)
|
||||
|
||||
The heatpump is 'Ultimate 12 Pro Plus Inverter', sold by ultimatemarket.com:
|
||||
Midea MSR1U-12HRDN1-QRC4W + MOB-12HFN1-QRC4W, with remote control RG51I20/BGE
|
||||
|
||||
This same sketch would also control the older 'Ultimate Pro Plus 13FP':
|
||||
Midea MSR1-12HRN1-QC2 + MOA1-12HN1-QC2 heatpump control, with remote control RG51M1/E
|
||||
|
||||
... and very likely many other Midea heatpumps...
|
||||
|
||||
|
||||
The Midea 'FP', or 'maintenance mode', is not really a mode even if the HeatpumpIR library
|
||||
interface makes it look like a mode. Instead it's a switch between the 'normal' and 'FP'
|
||||
mode, so to be absolutely sure about the operating mode, we need to turn the heatpump OFF
|
||||
first, and then turn it on (goes into 'normal' mode), and finally switch into 'FP'.
|
||||
|
||||
The IR led is driven by a transistor amplifier. I used 2 ohms as the resistor. I might sound
|
||||
very small, but also the led operates on very short bursts. For example Panasonic uses 2 ohm
|
||||
resistor for the IR led on its remotes.
|
||||
*/
|
||||
|
||||
// Heatpump states
|
||||
const byte heatpumpOff = 0;
|
||||
const byte heatpumpNormal = 1;
|
||||
const byte heatpumpMaintenance = 2;
|
||||
|
||||
Button relay1 = Button(11,PULLUP); // Heatpump ON-OFF state
|
||||
Button relay2 = Button(12,PULLUP); // FP mode (maintenance heating at 8 degrees C) ON-OFF state
|
||||
|
||||
IRSender irSender(9); // IR led on Duemilanove digital pin 9
|
||||
|
||||
byte heatpumpState = heatpumpOff;
|
||||
|
||||
HeatpumpIR *heatpumpIR = new MideaHeatpumpIR();
|
||||
|
||||
void setup(){
|
||||
Serial.begin(9600);
|
||||
delay(500);
|
||||
Serial.println(F("Starting..."));
|
||||
}
|
||||
|
||||
void loop(){
|
||||
|
||||
if (relay1.isPressed()) {
|
||||
// Normal heating operation
|
||||
if (!relay2.isPressed() && heatpumpState != heatpumpNormal) {
|
||||
Serial.println(F("Normal heating operation"));
|
||||
|
||||
Serial.println(F("* Sending power OFF"));
|
||||
heatpumpIR->send(irSender, POWER_OFF, MODE_HEAT, FAN_2, 22, VDIR_UP, HDIR_AUTO);
|
||||
delay(15 * 1000); // 15 seconds, to allow full shutdown
|
||||
|
||||
Serial.println(F("* Sending normal heat command"));
|
||||
heatpumpIR->send(irSender, POWER_ON, MODE_HEAT, FAN_2, 22, VDIR_UP, HDIR_AUTO);
|
||||
heatpumpState = heatpumpNormal;
|
||||
|
||||
// Maintenance heating operation
|
||||
} else if (relay2.isPressed() && heatpumpState != heatpumpMaintenance) {
|
||||
Serial.println(F("Maintenance heating operation"));
|
||||
|
||||
Serial.println(F("* Sending power OFF"));
|
||||
heatpumpIR->send(irSender, POWER_OFF, MODE_HEAT, FAN_2, 22, VDIR_UP, HDIR_AUTO);
|
||||
delay(15 * 1000); // 15 seconds, to allow full shutdown
|
||||
|
||||
Serial.println(F("* Sending normal heat command"));
|
||||
heatpumpIR->send(irSender, POWER_ON, MODE_HEAT, FAN_2, 22, VDIR_UP, HDIR_AUTO);
|
||||
delay(5 * 1000); // 15 seconds, to allow full start before switching to maintenance
|
||||
|
||||
Serial.println(F("* Switching to maintenance heating"));
|
||||
heatpumpIR->send(irSender, POWER_ON, MODE_MAINT, FAN_3, 10, VDIR_UP, HDIR_AUTO);
|
||||
|
||||
heatpumpState = heatpumpMaintenance;
|
||||
}
|
||||
// Power OFF
|
||||
} else if (!relay1.isPressed() && heatpumpState != heatpumpOff) {
|
||||
heatpumpState = heatpumpOff;
|
||||
Serial.println(F("Sending power OFF"));
|
||||
heatpumpIR->send(irSender, POWER_OFF, MODE_HEAT, FAN_2, 22, VDIR_UP, HDIR_AUTO);
|
||||
}
|
||||
|
||||
delay(500); // 0.5 seconds delay
|
||||
}
|
||||
Reference in New Issue