HeatpumpIR library + sensors example to send IR commands to heatpumps
This commit is contained in:
@@ -0,0 +1,73 @@
|
||||
# MySensors example
|
||||
|
||||
This example shows how HeatpumpIR could be integrated with the MySensors sensor network. As this sensor sends infrared signals,
|
||||
the natural sensor type is 'S_IR'. The heatpump/air conditioner signals are really long, so the signals need to be encoded somehow.
|
||||
|
||||
In this example the idea is to encode just this information, using 24 bits of data
|
||||
* model code (see the index of the array heatpumpIR in the code)
|
||||
* power state (for the rest, see the HeatpumpIR.h file for the constants)
|
||||
* operating mode
|
||||
* fan speed
|
||||
* temperature (the temperature is directly the temperature in HEX)
|
||||
|
||||
```
|
||||
An example:
|
||||
00213416 (as an example of a valid code)
|
||||
2 = PanasonicJKE
|
||||
1 = Power ON
|
||||
3 = COOL
|
||||
4 = FAN 4
|
||||
16 = Temperature 22 degrees (0x16 = 22)
|
||||
```
|
||||
|
||||
This sketch creates three sensors:
|
||||
* S_IR
|
||||
* S_INFO
|
||||
* S_LIGHT
|
||||
|
||||
The S_INFO and S_LIGHT sensors are for Domoticz, as it does not currently (as of V2.3093) support infrared code sending through the S_IR sensor type.
|
||||
|
||||
## Sending the code
|
||||
### MYSController
|
||||
|
||||
* Select the IR sensor on the 'Heatpump Sensor 1.0' node
|
||||
* Select 'IR_SEND' as the subtype
|
||||
* Enter for example '00213416' as the payload
|
||||
|
||||
### Domoticz
|
||||
|
||||
As Domoticz does not really support sending IR code yet, the workaround is to use two sensors. When the node is connected, Domoticz should find two new devices
|
||||
* A 'Lighting 2 / AC' type sensor with name 'IR send'
|
||||
* A 'General / Text' type sensor with name 'Unknown' and Data '00000000'
|
||||
|
||||
To send a command, first add the sensors. Then update the data of the text sensor to contain the IR code to be sent, and then flip the switch to trigger the sending.
|
||||
The data can be updated through the JSON REST API, or through the Lua event scripts.
|
||||
|
||||
REST API example (assuming that the idx of the text sensor is 105 and the switch is 104, and Domoticz is at 192.168.0.4:8080):
|
||||
```
|
||||
http://192.168.0.4:8080/json.htm?type=command¶m=udevice&idx=105&nvalue=0&svalue=00213416
|
||||
http://192.168.0.4:8080/json.htm?type=command¶m=switchlight&idx=104&switchcmd=On
|
||||
```
|
||||
|
||||
Lua example:
|
||||
* Seems that the text sensor can't be updated through the commandArray...
|
||||
* So now when a device called 'trigger' changes, the text sensor value is first updated to '00213416', and then the IR signal is sent
|
||||
|
||||
```
|
||||
commandArray = {}
|
||||
|
||||
for key, value in pairs(devicechanged) do
|
||||
if (key == 'trigger') then
|
||||
|
||||
print("Heatpump script")
|
||||
commandArray['OpenURL']='http://192.168.0.4:8080/json.htm?type=command¶m=udevice&idx=105&nvalue=0&svalue=00213416'
|
||||
commandArray['IR send']='On'
|
||||
end
|
||||
end
|
||||
|
||||
return commandArray
|
||||
```
|
||||
|
||||
## Hardware
|
||||
|
||||
Use any ATMega328-based Arduino, connect the radio, and finally connect an infrared led (in series with a resistor, like 100 Ohm) between digital pin 3 and GND.
|
||||
Reference in New Issue