806 lines
29 KiB
Python
Executable File
806 lines
29 KiB
Python
Executable File
#!/usr/bin/env python3
|
|
|
|
""" Dynamically control fan speed according to hard drive temperature. """
|
|
|
|
__version__ = "1.2.6"
|
|
__author__ = "desbma"
|
|
__license__ = "GPLv3"
|
|
|
|
import argparse
|
|
import contextlib
|
|
import enum
|
|
import itertools
|
|
import logging
|
|
import logging.handlers
|
|
import operator
|
|
import os
|
|
import re
|
|
import shutil
|
|
import signal
|
|
import socket
|
|
import stat
|
|
import subprocess
|
|
import sys
|
|
import syslog
|
|
import threading
|
|
import time
|
|
|
|
import daemon
|
|
import daemon.pidfile
|
|
|
|
from hddfancontrol import bin_dep
|
|
from hddfancontrol import colored_logging
|
|
|
|
|
|
exit_evt = threading.Event()
|
|
|
|
|
|
class LoggingSysLogHandler(logging.Handler):
|
|
|
|
""" Class similar in goal to logging.handlers.SysLogHandler, but uses the syslog call instead of socket. """
|
|
|
|
def __init__(self, facility, options=syslog.LOG_PID):
|
|
syslog.openlog(logoption=options, facility=facility)
|
|
super().__init__()
|
|
|
|
def emit(self, record):
|
|
""" See logging.Handler.emit. """
|
|
msg = self.format(record)
|
|
h = logging.handlers.SysLogHandler
|
|
level = h.priority_names[h.priority_map[record.levelname]]
|
|
syslog.syslog(level, msg)
|
|
|
|
def close(self):
|
|
""" See logging.Handler.close. """
|
|
syslog.closelog()
|
|
super().close()
|
|
|
|
|
|
class Drive:
|
|
|
|
""" Drive represented by a device file like /dev/sdX. """
|
|
|
|
DriveState = enum.Enum("DriveState", ("UNKNOWN", "ACTIVE_IDLE", "STANDBY", "SLEEPING"))
|
|
|
|
HDPARM_GET_TEMP_HITACHI_REGEX = re.compile("drive temperature \(celsius\) is:\s*([0-9]*)")
|
|
HDPARM_GET_TEMP_HITACHI_ERROR_REGEX = re.compile("^SG_IO: .* sense data", re.MULTILINE)
|
|
HDPARM_GET_MODEL_REGEX = re.compile("Model Number:\s*(.*)")
|
|
|
|
def __init__(self, device_filepath, hddtemp_daemon_port):
|
|
assert(stat.S_ISBLK(os.stat(device_filepath).st_mode))
|
|
self.device_filepath = __class__.normalizeDrivePath(device_filepath)
|
|
self.stat_filepath = "/sys/block/%s/stat" % (os.path.basename(self.device_filepath))
|
|
self.hddtemp_daemon_port = hddtemp_daemon_port
|
|
self.pretty_name = self.getPrettyName()
|
|
self.logger = logging.getLogger(str(self))
|
|
self.supports_hitachi_temp_query = self.supportsHitachiTempQuery()
|
|
|
|
def __str__(self):
|
|
""" Return a pretty drive name. """
|
|
return self.pretty_name
|
|
|
|
def getPrettyName(self):
|
|
""" Return a pretty drive name. """
|
|
# get device metadata to grab model string
|
|
cmd = ("hdparm", "-I", self.device_filepath)
|
|
output = subprocess.check_output(cmd,
|
|
stdin=subprocess.DEVNULL,
|
|
stderr=subprocess.DEVNULL,
|
|
universal_newlines=True)
|
|
model = __class__.HDPARM_GET_MODEL_REGEX.search(output).group(1).strip()
|
|
return "%s %s" % (os.path.basename(self.device_filepath), model)
|
|
|
|
def supportsHitachiTempQuery(self):
|
|
# test if drive supports hdparm -H
|
|
supported = True
|
|
cmd = ("hdparm", "-H", self.device_filepath)
|
|
try:
|
|
output = subprocess.check_output(cmd,
|
|
stdin=subprocess.DEVNULL,
|
|
stderr=subprocess.STDOUT,
|
|
universal_newlines=True)
|
|
except subprocess.CalledProcessError:
|
|
supported = False
|
|
else:
|
|
# catch non fatal errors
|
|
# see: https://github.com/Distrotech/hdparm/blob/4517550db29a91420fb2b020349523b1b4512df2/sgio.c#L308-L315
|
|
if __class__.HDPARM_GET_TEMP_HITACHI_ERROR_REGEX.search(output) is not None:
|
|
supported = False
|
|
if not supported:
|
|
self.logger.warning("Drive does not allow querying temperature without going out of low power mode.")
|
|
return supported
|
|
|
|
def getState(self):
|
|
""" Get drive power state, as a DriveState enum. """
|
|
states = {"unknown": __class__.DriveState.UNKNOWN,
|
|
"active/idle": __class__.DriveState.ACTIVE_IDLE,
|
|
"standby": __class__.DriveState.STANDBY,
|
|
"sleeping": __class__.DriveState.SLEEPING}
|
|
cmd = ("hdparm", "-C", self.device_filepath)
|
|
output = subprocess.check_output(cmd,
|
|
stdin=subprocess.DEVNULL,
|
|
stderr=subprocess.DEVNULL,
|
|
universal_newlines=True)
|
|
str_state = output.rsplit(" ", 1)[-1].strip()
|
|
state = states[str_state]
|
|
self.logger.debug("Drive state: %s" % (state.name))
|
|
return state
|
|
|
|
def isSleeping(self):
|
|
""" Return True if drive is in low power state, False otherwise. """
|
|
return (self.getState() in (Drive.DriveState.STANDBY, Drive.DriveState.SLEEPING))
|
|
|
|
def getTemperature(self):
|
|
""" Get drive temperature in Celcius using either hddtemp or hdparm. """
|
|
if not self.supports_hitachi_temp_query:
|
|
if self.hddtemp_daemon_port is not None:
|
|
# get temp from daemon
|
|
daemon_data = bytearray()
|
|
with socket.socket(socket.AF_INET, socket.SOCK_STREAM) as sckt:
|
|
sckt.connect(("127.0.0.1", self.hddtemp_daemon_port))
|
|
while True:
|
|
new_daemon_data = sckt.recv(4096)
|
|
if not new_daemon_data:
|
|
break
|
|
daemon_data.extend(new_daemon_data)
|
|
# parse it
|
|
daemon_data = daemon_data.decode("utf-8")
|
|
drives_data = iter(daemon_data.split("|")[:-1])
|
|
found = False
|
|
while True:
|
|
drive_data = tuple(itertools.islice(drives_data, 0, 5))
|
|
if not drive_data:
|
|
break
|
|
drive_path = drive_data[1]
|
|
if __class__.normalizeDrivePath(drive_path) == self.device_filepath:
|
|
temp_unit = drive_data[4]
|
|
if temp_unit != "C":
|
|
raise RuntimeError("hddtemp daemon is not returning temp as Celsius")
|
|
temp = int(drive_data[3])
|
|
found = True
|
|
break
|
|
if not found:
|
|
raise RuntimeError("Unable to get temperature from hddtemp daemon for drive %s" % (self))
|
|
else:
|
|
cmd = ("hddtemp", "-u", "C", "-n", self.device_filepath)
|
|
output = subprocess.check_output(cmd,
|
|
stdin=subprocess.DEVNULL,
|
|
stderr=subprocess.DEVNULL,
|
|
universal_newlines=True)
|
|
temp = int(output.strip())
|
|
else:
|
|
cmd = ("hdparm", "-H", self.device_filepath)
|
|
output = subprocess.check_output(cmd,
|
|
stdin=subprocess.DEVNULL,
|
|
stderr=subprocess.DEVNULL,
|
|
universal_newlines=True)
|
|
temp = int(__class__.HDPARM_GET_TEMP_HITACHI_REGEX.search(output).group(1))
|
|
self.logger.debug("Drive temperature: %u C" % (temp))
|
|
return temp
|
|
|
|
def spinDown(self):
|
|
""" Spin down a drive, effectively setting it to DriveState.STANDBY state. """
|
|
self.logger.info("Spinning down drive %s" % (self))
|
|
cmd = ("hdparm", "-y", self.device_filepath)
|
|
subprocess.check_call(cmd, stdin=subprocess.DEVNULL, stdout=subprocess.DEVNULL, stderr=subprocess.DEVNULL)
|
|
|
|
def getActivityStats(self):
|
|
""" Return drive stats as in /proc/diskstats, as a tuple of integer. """
|
|
with open(self.stat_filepath, "rt") as stat_file:
|
|
stats = stat_file.read()
|
|
stats = filter(None, map(str.strip, stats.strip().split(" ")))
|
|
stats = tuple(map(int, stats))
|
|
if not stats:
|
|
raise RuntimeError("Unable to get stats for drive %s" % (self))
|
|
return stats
|
|
|
|
@staticmethod
|
|
def normalizeDrivePath(path):
|
|
""" Normalize filepath by following symbolic links, and making it absolute. """
|
|
if os.path.islink(path):
|
|
r = os.readlink(path)
|
|
if not os.path.isabs(r):
|
|
r = os.path.join(os.path.dirname(path), r)
|
|
else:
|
|
r = path
|
|
return os.path.abspath(r)
|
|
|
|
|
|
class DriveSpinDownThread(threading.Thread):
|
|
|
|
""" Thread responsible for spinning down a drive when it is not active for a certain amount of time. """
|
|
|
|
def __init__(self, drive, spin_down_time_s):
|
|
super().__init__(name="%s-%s" % (__class__.__name__, drive))
|
|
self.drive = drive
|
|
self.spin_down_time_s = spin_down_time_s
|
|
self.logger = logging.getLogger(self.name)
|
|
|
|
def run(self):
|
|
""" Thread loop. """
|
|
try:
|
|
previous_stats = None
|
|
while not exit_evt.is_set():
|
|
if self.drive.isSleeping():
|
|
self.logger.debug("Drive is already sleeping")
|
|
self.sleep(60)
|
|
continue
|
|
|
|
if previous_stats is None:
|
|
# get stats
|
|
previous_stats = self.drive.getActivityStats()
|
|
previous_stats_time = time.monotonic()
|
|
|
|
# sleep
|
|
self.sleep(min(self.spin_down_time_s, 60))
|
|
if exit_evt.is_set():
|
|
break
|
|
|
|
# get stats again
|
|
stats = self.drive.getActivityStats()
|
|
now = time.monotonic()
|
|
if stats != previous_stats:
|
|
self.logger.debug("Drive is active")
|
|
previous_stats = None
|
|
else:
|
|
delta = now - previous_stats_time
|
|
self.logger.debug("Drive is inactive for %u min" % (int(delta / 60)))
|
|
if delta > self.spin_down_time_s:
|
|
self.drive.spinDown()
|
|
|
|
self.logger.info("Exiting")
|
|
|
|
except Exception as e:
|
|
self.logger.error("%s: %s" % (e.__class__.__qualname__, e))
|
|
|
|
def sleep(self, s):
|
|
""" Sleep for s seconds, or less if exit event occurs. """
|
|
self.logger.debug("Sleeping for %u seconds" % (s))
|
|
interrupted = exit_evt.wait(timeout=s)
|
|
if interrupted:
|
|
self.logger.debug("Sleep interrupted")
|
|
|
|
|
|
class Fan:
|
|
|
|
""" Represent a fan associated with a PWM file to control its speed. """
|
|
|
|
LAST_DIGITS_REGEX = re.compile("[^0-9]*([0-9]*)$")
|
|
|
|
def __init__(self, id, pwm_filepath, start_value, stop_value):
|
|
assert(0 <= start_value <= 255)
|
|
assert(0 <= stop_value <= 255)
|
|
self.id = id
|
|
self.pwm_filepath = pwm_filepath
|
|
if stat.S_ISBLK(os.stat(self.pwm_filepath).st_mode):
|
|
# we don't want to write to a block device in setPwmValue
|
|
# command line parameters have probably been mixed up
|
|
raise RuntimeError("%s is a block device, PWM /sys file expected" % (self.pwm_filepath))
|
|
pwm_num = int(__class__.LAST_DIGITS_REGEX.search(self.pwm_filepath).group(1))
|
|
self.fan_input_filepath = os.path.join(os.path.dirname(self.pwm_filepath),
|
|
"fan%u_input" % (pwm_num))
|
|
self.enable_filepath = "%s_enable" % (self.pwm_filepath)
|
|
self.start_value = start_value
|
|
self.stop_value = stop_value
|
|
self.startup = False
|
|
self.logger = logging.getLogger("Fan #%u" % (self.id))
|
|
|
|
def getRpm(self):
|
|
""" Read fan speed in revolutions per minute. """
|
|
with open(self.fan_input_filepath, "rt") as fan_input_file:
|
|
rpm = int(fan_input_file.read().strip())
|
|
self.logger.debug("Rotation speed is currently %u rpm" % (rpm))
|
|
return rpm
|
|
|
|
def isRunning(self):
|
|
""" Return True if fan is moving, False instead. """
|
|
return (self.getRpm() > 0)
|
|
|
|
def waitStabilize(self):
|
|
"""
|
|
Wait for the fan to have a stable rotational speed.
|
|
|
|
The algorithm only works if the fan is either slowing down, accelerating, or steady during the test, not if its speed
|
|
changes quickly ie. going up and down.
|
|
"""
|
|
rpm = self.getRpm()
|
|
min_rpm, max_rpm = rpm, rpm
|
|
while True:
|
|
time.sleep(2)
|
|
rpm = self.getRpm()
|
|
if min_rpm <= rpm <= max_rpm:
|
|
break
|
|
min_rpm = min(min_rpm, rpm)
|
|
max_rpm = max(max_rpm, rpm)
|
|
|
|
def setSpeed(self, speed_prct, min_prct):
|
|
""" Set fan speed to a percentage of its maximum speed. """
|
|
# preconditions
|
|
assert(0 <= speed_prct <= 100)
|
|
assert(0 <= min_prct <= 100)
|
|
|
|
self.logger.info("Setting fan speed to %u%%" % (speed_prct))
|
|
|
|
# calculate target PWM value
|
|
if speed_prct == 0:
|
|
target_value = 0
|
|
else:
|
|
target_value = self.stop_value + ((255 - self.stop_value) * speed_prct) // 100
|
|
if min_prct > 0:
|
|
min_value = self.stop_value + ((255 - self.stop_value) * min_prct) // 100
|
|
target_value = max(min_value, target_value)
|
|
|
|
if (0 < target_value < self.start_value) and (not self.isRunning()):
|
|
self.startup = True
|
|
else:
|
|
self.startup = False
|
|
|
|
# set speed
|
|
if self.startup:
|
|
# fan startup boost
|
|
self.logger.debug("Applying startup boost")
|
|
self.setPwmValue(self.start_value)
|
|
else:
|
|
self.setPwmValue(target_value)
|
|
|
|
def setPwmValue(self, value):
|
|
""" Set fan PWM value. """
|
|
assert(0 <= value <= 255)
|
|
with open(self.enable_filepath, "r+t") as enable_file:
|
|
enabled_val = int(enable_file.read().strip())
|
|
if enabled_val != 1:
|
|
self.logger.warning("%s was %u, setting it to 1", self.enable_filepath, enabled_val)
|
|
enable_file.seek(0)
|
|
enable_file.write("1")
|
|
self.logger.debug("Setting PWM value to %u" % (value))
|
|
with open(self.pwm_filepath, "wt") as pwm_file:
|
|
pwm_file.write("%u" % (value))
|
|
|
|
|
|
class TestHardware:
|
|
|
|
""" Run basic drive tests, and analyze fan start/stop behaviour. """
|
|
|
|
def __init__(self, drives, fans):
|
|
self.drives = drives
|
|
self.fans = fans
|
|
self.ok_count = 0
|
|
self.ko_count = 0
|
|
self.logger = logging.getLogger(__class__.__name__)
|
|
|
|
def run(self):
|
|
self.logger.info("Running hardware tests, this may take a few minutes")
|
|
self.testDrives()
|
|
start_stop_values = self.testPwms()
|
|
if self.ko_count > 0:
|
|
print("%u/%u tests failed!" % (self.ko_count, self.ko_count + self.ok_count))
|
|
else:
|
|
print("%u/%u tests OK, all good :)" % (self.ok_count, self.ok_count))
|
|
self.logger.info("Recommended parameters: --pwm-start-value %s --pwm-stop-value %s"
|
|
% (" ".join(str(min(255, x[0] + 32)) for x in start_stop_values),
|
|
" ".join(str(x[1]) for x in start_stop_values)))
|
|
|
|
def testDrives(self):
|
|
for drive in self.drives:
|
|
self.reportTestGroupStart("Test of drive %s" % (drive))
|
|
|
|
test_desc = "Getting drive power state"
|
|
self.reportTestStart(test_desc)
|
|
try:
|
|
state = drive.getState()
|
|
test_ok = state in Drive.DriveState
|
|
except:
|
|
test_ok = False
|
|
self.reportTestResult(test_desc, test_ok)
|
|
|
|
test_desc = "Getting drive temperature"
|
|
self.reportTestStart(test_desc)
|
|
try:
|
|
temp = drive.getTemperature()
|
|
test_ok = isinstance(temp, int)
|
|
except:
|
|
test_ok = False
|
|
self.reportTestResult(test_desc, test_ok)
|
|
|
|
test_desc = "Getting drive activity statistics"
|
|
self.reportTestStart(test_desc)
|
|
try:
|
|
stats = drive.getActivityStats()
|
|
test_ok = isinstance(stats, tuple)
|
|
except:
|
|
test_ok = False
|
|
self.reportTestResult(test_desc, test_ok)
|
|
|
|
def testPwms(self):
|
|
start_stop_values = []
|
|
pwm_vals = (255,) + tuple(range(240, -1, -16))
|
|
for fan in self.fans:
|
|
self.reportTestGroupStart("Test of fan #%u" % (fan.id))
|
|
start_value, stop_value = 255, 0
|
|
|
|
test_desc = "Stopping fan"
|
|
self.reportTestStart(test_desc)
|
|
try:
|
|
fan.setPwmValue(0)
|
|
fan.waitStabilize()
|
|
test_ok = not fan.isRunning()
|
|
except:
|
|
test_ok = False
|
|
self.reportTestResult(test_desc, test_ok)
|
|
|
|
test_desc = "Starting fan"
|
|
self.reportTestStart(test_desc)
|
|
try:
|
|
fan.setPwmValue(255)
|
|
fan.waitStabilize()
|
|
test_ok = fan.isRunning()
|
|
except:
|
|
test_ok = False
|
|
self.reportTestResult(test_desc, test_ok)
|
|
|
|
test_desc = "Finding exact start value of fan"
|
|
self.reportTestStart(test_desc)
|
|
test_ok = False
|
|
try:
|
|
for v in reversed(pwm_vals):
|
|
fan.setPwmValue(v)
|
|
fan.waitStabilize()
|
|
test_ok = fan.isRunning()
|
|
if test_ok:
|
|
start_value = v
|
|
break
|
|
except:
|
|
pass
|
|
self.reportTestResult(test_desc, test_ok)
|
|
|
|
test_desc = "Finding exact stop value of fan"
|
|
self.reportTestStart(test_desc)
|
|
test_ok = False
|
|
try:
|
|
for v in pwm_vals:
|
|
fan.setPwmValue(v)
|
|
fan.waitStabilize()
|
|
test_ok = not fan.isRunning()
|
|
if test_ok:
|
|
stop_value = v
|
|
break
|
|
except:
|
|
pass
|
|
self.reportTestResult(test_desc, test_ok)
|
|
|
|
start_stop_values.append((start_value, stop_value))
|
|
|
|
return start_stop_values
|
|
|
|
def reportTestGroupStart(self, desc):
|
|
print("%s %s" % (desc, "-" * (shutil.get_terminal_size()[0] - len(desc) - 1)))
|
|
|
|
def reportTestStart(self, desc):
|
|
print(desc, end=" ", flush=True)
|
|
|
|
def reportTestResult(self, desc, ok):
|
|
if ok:
|
|
self.ok_count += 1
|
|
else:
|
|
self.ko_count += 1
|
|
print(("[ %s ]" % ("OK" if ok else "KO")).rjust(shutil.get_terminal_size()[0] - len(desc) - 1))
|
|
|
|
|
|
def test(drive_filepaths, fan_pwm_filepaths, hddtemp_daemon_port):
|
|
fans = [Fan(i, fan_pwm_filepath, 0, 0) for i, fan_pwm_filepath in enumerate(fan_pwm_filepaths, 1)]
|
|
drives = [Drive(drive_filepath, hddtemp_daemon_port) for drive_filepath in drive_filepaths]
|
|
|
|
tester = TestHardware(drives, fans)
|
|
tester.run()
|
|
|
|
|
|
def signal_handler(sig, frame):
|
|
logging.getLogger("Signal handler").info("Catched signal %u" % (sig))
|
|
global exit_evt
|
|
exit_evt.set()
|
|
|
|
|
|
def set_high_priority(logger):
|
|
""" Change process priority to the highest possible. """
|
|
# use "real time" scheduler
|
|
done = False
|
|
sched = os.SCHED_RR
|
|
prio = os.sched_get_priority_max(sched)
|
|
param = os.sched_param(prio)
|
|
try:
|
|
os.sched_setscheduler(0, sched, param)
|
|
except OSError:
|
|
logger.warning("Failed to set real time process scheduler to %u, priority %u" % (sched, prio))
|
|
else:
|
|
done = True
|
|
logger.info("Process real time scheduler set to %u, priority %u" % (sched, prio))
|
|
|
|
if not done:
|
|
# renice to highest priority
|
|
target_niceness = -19
|
|
previous_niceness = os.nice(0)
|
|
delta_niceness = target_niceness - previous_niceness
|
|
try:
|
|
new_niceness = os.nice(delta_niceness)
|
|
except OSError:
|
|
new_niceness = previous_niceness
|
|
if new_niceness != target_niceness:
|
|
logger.warning("Unable to renice process to %d, current niceness is %d" % (target_niceness, new_niceness))
|
|
else:
|
|
logger.info("Process reniced from %d to %d" % (previous_niceness, new_niceness))
|
|
|
|
|
|
def main(drive_filepaths, fan_pwm_filepaths, fan_start_values, fan_stop_values, min_fan_speed_prct, min_temp, max_temp,
|
|
interval_s, spin_down_time_s, hddtemp_daemon_port):
|
|
logger = logging.getLogger("Main")
|
|
fans = []
|
|
try:
|
|
# change process priority
|
|
set_high_priority(logger)
|
|
|
|
# register signal handler
|
|
signal.signal(signal.SIGINT, signal_handler)
|
|
signal.signal(signal.SIGTERM, signal_handler)
|
|
|
|
# init
|
|
fans = [Fan(i,
|
|
fan_pwm_filepath,
|
|
fan_start_value,
|
|
fan_stop_value) for i,
|
|
(fan_pwm_filepath,
|
|
fan_start_value,
|
|
fan_stop_value) in enumerate(zip(fan_pwm_filepaths,
|
|
fan_start_values,
|
|
fan_stop_values),
|
|
1)]
|
|
drives = [Drive(drive_filepath, hddtemp_daemon_port) for drive_filepath in drive_filepaths]
|
|
drives_startup_time = time.monotonic()
|
|
current_fan_speeds = [None] * len(fans)
|
|
|
|
# start spin down threads if needed
|
|
spin_down_threads = []
|
|
if (spin_down_time_s is not None) and (spin_down_time_s > interval_s):
|
|
for drive in drives:
|
|
spin_down_threads.append(DriveSpinDownThread(drive, spin_down_time_s))
|
|
for thread in spin_down_threads:
|
|
thread.start()
|
|
|
|
while not exit_evt.is_set():
|
|
now = time.monotonic()
|
|
|
|
# calc max drive temperature
|
|
temps = []
|
|
awakes = []
|
|
for drive in drives:
|
|
awake = not drive.isSleeping()
|
|
awakes.append(awake)
|
|
if awake or drive.supports_hitachi_temp_query:
|
|
temps.append(drive.getTemperature())
|
|
else:
|
|
logger.debug("Drive %s is in low power state, unable to query temperature" % (drive))
|
|
if temps:
|
|
temp = max(temps)
|
|
logger.info("Maximum drive temperature: %u C" % (temp))
|
|
else:
|
|
assert(not any(awakes))
|
|
logger.info("All drives are in low power state")
|
|
|
|
if not any(awakes):
|
|
drives_startup_time = now
|
|
|
|
# calc target percentage fan speed
|
|
if temps and (temp - min_temp > 0):
|
|
speed_prct = 100 * (temp - min_temp) // (max_temp - min_temp)
|
|
speed_prct = int(min(speed_prct, 100))
|
|
else:
|
|
speed_prct = 0
|
|
|
|
# set fan speed if needed
|
|
for i, fan in enumerate(fans):
|
|
if current_fan_speeds[i] != speed_prct:
|
|
fan.setSpeed(speed_prct, min_fan_speed_prct)
|
|
current_fan_speeds[i] = speed_prct
|
|
|
|
# sleep
|
|
if any(map(operator.attrgetter("startup"), fans)):
|
|
# at least one fan is starting up, quickly cancel startup boost
|
|
current_interval_s = min(10, interval_s)
|
|
elif any(awakes) and ((now - drives_startup_time) < (60 * 5)):
|
|
# if at least a drive was started or waken up less than 5 min ago, dont' sleep too long because it
|
|
# can heat up quickly
|
|
current_interval_s = min(20, interval_s)
|
|
else:
|
|
current_interval_s = interval_s
|
|
logger.debug("Sleeping for %u seconds" % (current_interval_s))
|
|
exit_evt.wait(current_interval_s)
|
|
|
|
logger.info("Exiting")
|
|
|
|
for thread in spin_down_threads:
|
|
thread.join()
|
|
|
|
except Exception as e:
|
|
logger.error("%s: %s" % (e.__class__.__qualname__, e))
|
|
|
|
# run fans at full speed at exit
|
|
for fan in fans:
|
|
fan.setSpeed(100, 100)
|
|
|
|
|
|
def cl_main():
|
|
# parse args
|
|
arg_parser = argparse.ArgumentParser(description="HDD Fan Control v%s.%s" % (__version__, __doc__),
|
|
formatter_class=argparse.ArgumentDefaultsHelpFormatter)
|
|
arg_parser.add_argument("-d",
|
|
"--drives",
|
|
required=True,
|
|
nargs="+",
|
|
dest="drive_filepaths",
|
|
help="Drive(s) to get temperature from (ie. /dev/sdX)")
|
|
arg_parser.add_argument("-p",
|
|
"--pwm",
|
|
required=True,
|
|
nargs="+",
|
|
dest="fan_pwm_filepath",
|
|
help="PWM filepath(s) to control fan speed (under /sys)")
|
|
arg_parser.add_argument("--pwm-start-value",
|
|
type=int,
|
|
default=None,
|
|
nargs="+",
|
|
dest="fan_start_value",
|
|
help="""PWM value (0-255), at which the fan starts moving.
|
|
Use the -t parameter, or run pwmconfig to find this value.""")
|
|
arg_parser.add_argument("--pwm-stop-value",
|
|
type=int,
|
|
default=None,
|
|
nargs="+",
|
|
dest="fan_stop_value",
|
|
help="""PWM value (0-255), at which the fan stop moving.
|
|
Use the -t parameter, or run pwmconfig to find this value.
|
|
Often 20-40 lower than start speed.""")
|
|
arg_parser.add_argument("--min-temp",
|
|
type=int,
|
|
default=30,
|
|
dest="min_temp",
|
|
help="Temperature in Celcius at which the fan(s) will be set to minimum speed.")
|
|
arg_parser.add_argument("--max-temp",
|
|
type=int,
|
|
default=50,
|
|
dest="max_temp",
|
|
help="Temperature in Celcius at which the fan(s) will be set to maximum speed.")
|
|
arg_parser.add_argument("--min-fan-speed-prct",
|
|
type=int,
|
|
default=20,
|
|
dest="min_fan_speed_prct",
|
|
help="""Minimum percentage of full fan speed to set the fan to.
|
|
Never set to 0 unless you have other fans to cool down your system,
|
|
or a case specially designed for passive cooling.""")
|
|
arg_parser.add_argument("-i",
|
|
"--interval",
|
|
type=int,
|
|
default=60,
|
|
dest="interval_s",
|
|
help="Interval in seconds to check temperature and adjust fan speed.")
|
|
arg_parser.add_argument("--spin-down-time",
|
|
type=int,
|
|
default=None,
|
|
dest="spin_down_time_s",
|
|
help="Interval in seconds after which inactive drives will be put to standby state.")
|
|
arg_parser.add_argument("-v",
|
|
"--verbosity",
|
|
choices=("warning", "normal", "debug"),
|
|
default="normal",
|
|
dest="verbosity",
|
|
help="Level of logging output")
|
|
arg_parser.add_argument("-b",
|
|
"--background",
|
|
action="store_true",
|
|
dest="daemonize",
|
|
help="Daemonize process")
|
|
arg_parser.add_argument("-l",
|
|
"--log-file",
|
|
default=None,
|
|
dest="log_filepath",
|
|
help="Filepath for log output when using daemon mode, if omitted, logging goes to syslog.")
|
|
arg_parser.add_argument("--pid-file",
|
|
default="/var/run/hddfancontrol.pid",
|
|
dest="pid_filepath",
|
|
help="Filepath for lock file when using daemon mode")
|
|
arg_parser.add_argument("-t",
|
|
"--test",
|
|
action="store_true",
|
|
default=False,
|
|
dest="test_mode",
|
|
help="Run some tests and exit")
|
|
arg_parser.add_argument("--hddtemp-daemon",
|
|
action="store_true",
|
|
default=False,
|
|
dest="hddtemp_daemon",
|
|
help="""Get drive temperature from hddtemp daemon instead of spawning
|
|
a new process each time temperature is probed""")
|
|
arg_parser.add_argument("--hddtemp-daemon-port",
|
|
type=int,
|
|
default=7634,
|
|
dest="hddtemp_daemon_port",
|
|
help="hddtemp daemon port if option --hddtemp-daemon is used")
|
|
args = arg_parser.parse_args()
|
|
if (((args.fan_start_value is not None) and (len(args.fan_pwm_filepath) != len(args.fan_start_value))) or
|
|
((args.fan_stop_value is not None) and (len(args.fan_pwm_filepath) != len(args.fan_stop_value)))):
|
|
print("Invalid parameter count")
|
|
exit(1)
|
|
|
|
# setup logger
|
|
logging_level = {"warning": logging.WARNING,
|
|
"normal": logging.INFO,
|
|
"debug": logging.DEBUG}
|
|
logging.getLogger().setLevel(logging_level[args.verbosity])
|
|
logging_fmt_long = "%(asctime)s %(levelname)s [%(name)s] %(message)s"
|
|
logging_fmt_short = "%(levelname)s [%(name)s] %(message)s"
|
|
if args.daemonize:
|
|
if args.log_filepath is not None:
|
|
# log to file
|
|
logging_fmt = logging_fmt_long
|
|
logging_handler = logging.handlers.WatchedFileHandler(args.log_filepath)
|
|
else:
|
|
# log to syslog
|
|
logging_fmt = logging_fmt_short
|
|
logging_handler = LoggingSysLogHandler(syslog.LOG_DAEMON)
|
|
logging_formatter = logging.Formatter(fmt=logging_fmt)
|
|
else:
|
|
# log to stderr
|
|
if sys.stderr.isatty():
|
|
logging_formatter = colored_logging.ColoredFormatter(fmt=logging_fmt_long)
|
|
else:
|
|
# assume systemd service in 'simple' mode
|
|
logging_formatter = logging.Formatter(fmt=logging_fmt_short)
|
|
logging_handler = logging.StreamHandler()
|
|
logging_handler.setFormatter(logging_formatter)
|
|
logging.getLogger().addHandler(logging_handler)
|
|
|
|
# check if root
|
|
if os.geteuid() != 0:
|
|
logging.getLogger("Startup").error("You need to run this script as root")
|
|
exit(1)
|
|
|
|
if args.test_mode or (args.fan_start_value is None) or (args.fan_stop_value is None):
|
|
if (args.fan_start_value is None) or (args.fan_stop_value is None):
|
|
logging.getLogger("Startup").warning("Missing --pwm-start-value or --pwm-stop-value argument, running hardware test to find values")
|
|
test(args.drive_filepaths,
|
|
args.fan_pwm_filepath,
|
|
args.hddtemp_daemon_port if args.hddtemp_daemon else None)
|
|
|
|
else:
|
|
# main
|
|
with contextlib.ExitStack() as daemon_context:
|
|
if args.daemonize:
|
|
preserved_fds = None
|
|
if args.log_filepath is not None:
|
|
preserved_fds = [logging_handler.stream.fileno()]
|
|
if args.pid_filepath is not None:
|
|
pidfile = daemon.pidfile.PIDLockFile(args.pid_filepath)
|
|
if pidfile.is_locked():
|
|
logging.getLogger("Startup").error("Daemon already running")
|
|
exit(1)
|
|
else:
|
|
pidfile = None
|
|
daemon_context.enter_context(daemon.DaemonContext(pidfile=pidfile,
|
|
files_preserve=preserved_fds))
|
|
main(args.drive_filepaths,
|
|
args.fan_pwm_filepath,
|
|
args.fan_start_value,
|
|
args.fan_stop_value,
|
|
args.min_fan_speed_prct,
|
|
args.min_temp,
|
|
args.max_temp,
|
|
args.interval_s,
|
|
args.spin_down_time_s,
|
|
args.hddtemp_daemon_port if args.hddtemp_daemon else None)
|
|
|
|
|
|
# check deps
|
|
bin_dep.check_bin_dependency(("hddtemp", "hdparm"))
|
|
|
|
|
|
if __name__ == "__main__":
|
|