Corrected 1Mhz operating frequency
This commit is contained in:
@@ -58,6 +58,7 @@ MyMessage msgTemp(CHILD_ID_TEMP, V_TEMP);
|
||||
int measureCount = 0;
|
||||
int sendBattery = 0;
|
||||
boolean isMetric = true;
|
||||
boolean highfreq = true;
|
||||
|
||||
// Storage of old measurements
|
||||
float lastTemperature = -100;
|
||||
@@ -73,12 +74,11 @@ RunningAverage raTemp(AVERAGES);
|
||||
*
|
||||
****************************************************/
|
||||
void setup() {
|
||||
// clock_prescale_set(clock_div_8); // Switch to 1Mhz right after powerup.
|
||||
|
||||
pinMode(LED_PIN, OUTPUT);
|
||||
digitalWrite(LED_PIN, LOW);
|
||||
|
||||
Serial.begin(19200);
|
||||
Serial.begin(115200);
|
||||
Serial.print(F("Sensebender Micro FW "));
|
||||
Serial.print(RELEASE);
|
||||
Serial.flush();
|
||||
@@ -131,6 +131,12 @@ void loop() {
|
||||
sendBattery ++;
|
||||
bool forceTransmit = false;
|
||||
|
||||
if ((measureCount == 5) && highfreq)
|
||||
{
|
||||
clock_prescale_set(clock_div_8); // Switch to 1Mhz for the reminder of the sketch, save power.
|
||||
highfreq = false;
|
||||
}
|
||||
|
||||
if (measureCount > FORCE_TRANSMIT_INTERVAL) { // force a transmission
|
||||
forceTransmit = true;
|
||||
measureCount = 0;
|
||||
|
||||
Reference in New Issue