Commit Graph
267 Commits
Author SHA1 Message Date
Patrick Fallberg 963a756605 sha204 library extended with CRC calculator
Locking operations are recommended to include CRC
and since sha204 library internally carries the proper
algorithm for this, it has now been refactored to support
both static and incremental calculations needed for both
command marchalling and locking.
2015-01-10 18:39:47 +01:00
Patrick Fallberg 1ac6f0a291 Removed examples from sha204 libraries
MySensors will have native support for sha204 and the
source for usage and personalization of sha204 will be
much more elaborate than this example so it does not
provide additional understanding for the chip.
2015-01-10 18:39:46 +01:00
Patrick Fallberg 9fd41b4030 Added sha204 library
Taken from the sha204_library folder in
https://github.com/jimblom/sha204-Breakout
Commit 8e1ac05ef987b1869605ad067db2bdbaec1c109f

ATSHA204 is a crypto cirquit from Atmel that enables
SHA256-based MAC and HMAC calculations as well as
secure key storage and random number generation.

This can be used to sign messages passed between
sensor nodes and prevent both man-in-the-middle and
replay attacking.
2015-01-10 18:37:43 +01:00
Henrik Ekblad afe506f79a Merge pull request #40 from portals12/PressureSensor-example-fix
Fix stupid errors from the last pull request
2015-01-02 12:18:04 +01:00
Piotr 021867784e Fix stupid errors from the last pull request 2015-01-02 11:09:32 +01:00
Henrik Ekblad d6922e7501 Merge branch 'master' of https://github.com/mysensors/Arduino.git 2014-12-30 13:46:21 +01:00
Henrik Ekblad 0b9178318e Set empty payload when requesting data. 2014-12-30 13:42:10 +01:00
Piotr 77d5cfdb09 Limit memory usage of forecast algorithm. Now it's not running out of memory 2014-12-21 12:11:54 +01:00
Piotr 05c07cd0e0 Limit memory usage of forecast algorithm. Now it's not running out of memory 2014-12-21 12:06:03 +01:00
Henrik Ekblad 55c1fe8d01 MAX6875 Temp Sensor example 2014-12-07 10:23:41 +01:00
Henrik Ekblad 0dd6687488 Merge branch 'master' into development
Conflicts:
	libraries/MySensors/MySensor.cpp
	libraries/MySensors/examples/EthernetGateway/EthernetGateway.ino
2014-11-25 16:52:07 +01:00
Henrik Ekblad 843e163328 Update BMP085 library.
And additional pressure sensor problems repoted by @MagKas.
http://forum.mysensors.org/topic/631/pressure-sensor-arduino-low-memory
2014-11-25 16:18:40 +01:00
Henrik Ekblad ab3db8b28b Fix bug in PressureSensor. 2014-11-25 15:48:10 +01:00
Henrik Ekblad 25230d7ef8 Update Time library to work on IDE 1.5.8
Also removed a few large pdfs from UTFT library to make library compile
on codebender (a but that they will fix eventually).
2014-11-19 09:03:51 +01:00
Henrik Ekblad 024d6efb82 Ethernet SoftSPI
Update ethernet sketch to give correct instructions when using
W5100/SoftSPI.
2014-11-14 00:36:49 +01:00
Henrik Ekblad f143fcd7a2 Moved RFM69 library to utility 2014-11-03 20:08:56 +01:00
Frank Olaf Sem-Jacobsen db73e3c788 switched to low-power library 2014-11-03 19:21:40 +01:00
Frank Olaf Sem-Jacobsen 26138b7972 RF69 2014-10-31 20:27:20 +01:00
Henrik Ekblad 4783cac945 Set version to 1.4.1 2014-10-31 07:21:57 +01:00
Henrik Ekblad abe3956f5e Fixed bug resulting in ACK problems
Even thouh auto ack was enabled we still called
RF24::writeAckPayload(pipe,&pipe, 1 ); after reading a message.
This probably caused radio to misbehave.
2014-10-29 18:00:34 +01:00
Henrik Ekblad 3d2d7db845 Fix problem reported by Yveaux here:
https://github.com/mysensors/Arduino/commit/aeb9f30482532122b624fe4f061b5176571b0c6b#commitcomment-8300974
2014-10-25 10:49:32 +02:00
Henrik Ekblad 8ec2ebdfce Sent startup message to controller when it connects. 2014-10-23 09:02:30 +02:00
Henrik Ekblad b0057cc152 Merge branch 'tosa' of https://github.com/ToSa27/Arduino into
ToSa27-tosa

Conflicts:
	libraries/MySensors/examples/EthernetGateway/EthernetGateway.ino
2014-10-23 00:30:01 +02:00
Henrik Ekblad 301296359b Merge branch 'master' into development
Conflicts:
	libraries/UIPEthernet/utility/uipethernet-conf.h
2014-10-22 00:15:56 +02:00
Henrik Ekblad 9329626e8b Update to latest UIPEthernet library 2014-10-22 00:11:38 +02:00
Henrik Ekblad 3127b1549a Merge branch 'development' of https://github.com/mysensors/Arduino.git into development 2014-10-21 23:47:04 +02:00
Henrik Ekblad d5ca838371 Update UIPEthernet library 2014-10-21 23:44:52 +02:00
Henrik Ekblad 91e913f854 Update include statement resulting in compile error. 2014-10-17 16:41:58 +02:00
Henrik Ekblad c2acbac2e0 Forgot to enable MINIMAL mode for RF24 in the latest commit. 2014-10-17 00:07:15 +02:00
Henrik Ekblad 2fd948fc66 Add new scene controller with touch display example.
Upgraded RF24 to latest version which supports SoftSPI. 
Added DigitalIO and UTFT libraries to support the new example.
Fix problem reported in RelayWithButtonActuator example.
2014-10-17 00:01:55 +02:00
Patrick Fallberg 99b7b12856 Merge remote-tracking branch 'upstream/development' into development
Conflicts:
	libraries/MySensors/examples/EthernetGateway/EthernetGateway.ino
2014-10-11 00:00:27 +02:00
Patrick Fallberg f5ef712308 Support for WIZnet W5100 ethernet module SPI_EN
The W5100 module has a SPI_EN signal that enables or disables the SPI
bus.
A bug in the module causes MISO to be continously driven by the module
when SPI_EN is pulled high. This is described in this application note:
https://www.google.se/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&cad=rja&uact=8&ved=0CCAQFjAA&url=http%3A%2F%2Fwww.wiznet.co.kr%2FUpLoad_Files%2FReferenceFiles%2FW5100_AN_SPI.pdf&ei=ij84VK7uM6nNygPqvICYDw&usg=AFQjCNGz1qttBEwG1azc1Eza4j69v1rpDQ&sig2=UUUtb4Dr0F35g8ByHMsyig&bvm=bv.77161500,d.bGQ

This commit changes the Ethernet gateway sketch to drive SPI_EN high or
low, depending on which module is in use (SPI bus is shared between
Ethernet and RF modules).
The pin attached to SPI_EN is defined by W5100_SPI_EN. This define can
be commented out if SPI_EN is not needed (different module) or if the
module manages SPI_EN in hardware (some W5100 shields does this).
2014-10-10 22:39:47 +02:00
ToSa27 2647345c4d Adding defines for different board layouts in MyConfig
Adjusted all Gateway examples but only one sensor example so far
(DallasTemperature). Other sensor examples should get the same three
lines added (not mandatory but helps avoiding unnecessary debugging when
selecting the wrong setup)
2014-09-29 10:33:16 +02:00
ToSa27 39bab3dfba Split Application and Driver Layer 2014-09-29 00:24:57 +02:00
ToSa27 c3dbcd1fea Accept Time Broadcasts
NodeJsController sending Time broadcasts every few minutes.
Sensor accepting not just Time messages addressed to the specific
sensor.
2014-09-28 23:47:22 +02:00
Henrik Ekblad f71ed97aaa Made Time, LiquidCrystal and RealTimeClockDisplaySensor example work in Arduino IDE 1.5.7. 2014-09-20 13:04:01 +02:00
Henrik Ekblad 82dda0fe30 Merge branch 'master' into development 2014-09-16 22:19:21 +02:00
Henrik Ekblad 26129b06a9 Upgrade UIP-library to latest. Recommend Arduino IDE 1.5.7 when compiling EtherentGateway sketch. 2014-09-16 22:17:07 +02:00
Henrik Ekblad 27885fad9b Prefix enums to proghibit name clash with other libraries. 2014-09-15 19:29:42 +02:00
Henrik Ekblad 78b5df44b4 Remove spam from pulse sensors when gateway is unable to receive request for meter value. 2014-09-15 13:48:44 +02:00
Henrik Ekblad 86b6411280 Merge branch 'hek-gateway-rework' into development
Conflicts:
	libraries/MySensors/MySensor.cpp
	libraries/MySensors/MySensor.h
2014-09-11 09:56:30 +02:00
Henrik Ekblad d8ba222759 Merge branch 'master' into development 2014-09-11 09:51:59 +02:00
Yveaux e5bd891a77 Improved parent node search
Retry parent node search with each transmit when parent has not been
found.
Transmit does not block on transmit when no parent has been found as
this depletes batteries on battery powered nodes.
Fix nRF24 configuration for dynamic ACK's. This bug caused broadcasts to
be sent with auto-ACK's.
To not break existing functionality parent search can be started when
node ID is still unknown. In this case node ID is set to broadcast ID,
which can cause funky stuff to happen...
2014-09-11 09:37:42 +02:00
Henrik Ekblad bfd589455b Add new example showing RTC with LCD display. 2014-09-11 00:45:56 +02:00
Henrik Ekblad 5bb8c9b40c Bugfixes and cleanup 2014-09-09 22:33:49 +02:00
Henrik Ekblad 7fa54a6e5a Proposal to keep gateways separated. 2014-09-09 16:57:56 +02:00
Henrik Ekblad 9192da3a7d Fix another problem related to config from controller (reading wrong position at startup!). Bugfix. Only strip carriage return on serial data from controller (at gateway) 2014-09-08 19:56:09 +02:00
Henrik Ekblad bf341ab49c Node id is a string and must be parsed. The getByte does not parse any more. 2014-09-08 07:32:16 +02:00
Daniel Wiegert 159c223882 Include more debug text in MINIMAL definition, and enable MINIMAL as default, saves 432bytes 2014-09-07 23:58:18 +02:00
Henrik Ekblad ba098a95e2 Fix compiler error. 2014-09-07 23:58:18 +02:00