Thomas Mørch
5b3fac51cc
Changed HW signing (atsha204) to be SAMD compatible
2015-12-06 23:16:44 +01:00
Thomas Mørch
c62aca4125
Added ethernet module to local hardware instance, since we have to hack it a bit in order to move it to alternative SPI port
...
Removed Wire and SAMD_AnalogCorrection libraries from HW section, as we didn't change anything in those, so let's keep it to the standard ones
Modified SPI library, initializing extra SPI ports, also HW mux changes in the setup of individual SPI ports to match the GW setup
Added MyHWSAMD files so they are included in the core headers (MyConfig.h / MySensors.h)
2015-12-06 23:16:44 +01:00
Thomas Mørch
e229e21d0e
Initial commit for SAMD compatability
2015-12-06 23:16:44 +01:00
Henrik Ekblad
9540cb2b30
Merge pull request #277 from mysensors/esp8266-2.0.0-compability-fix
...
Fix compile error using ESP board 2.0.0
2015-12-03 16:35:09 +01:00
Henrik Ekblad
9ad98582c5
Fix compile error using ESP board 2.0.0
...
You need to update to the latest ESP board files 2.0.0 by using
Tools->Board->Boards-Manager. Select ESP8266 and press Update.
2015-12-03 09:34:44 +01:00
Henrik Ekblad
a53b470f87
Merge pull request #274 from fallberg/print-fix
...
Let prints on GW:s be up to MY_GATEWAY_MAX_SEND_LENGTH large
2015-11-30 21:59:04 +01:00
Patrick Fallberg
36dcf2b5b6
Let prints on GW:s be up to MY_GATEWAY_MAX_SEND_LENGTH large
2015-11-30 14:16:58 +01:00
Patrick Fallberg
654e804744
Merge pull request #273 from mysensors/null-check-fix
2015-11-30 07:24:57 +01:00
Henrik Ekblad
6d97702b29
Fix #272 - NULL argument check in MyMessage::set(char *)
2015-11-30 00:08:48 +01:00
Henrik Ekblad
7f468df165
Merge pull request #271 from mysensors/smart-sleep
...
Smart sleep
2015-11-28 23:30:11 +01:00
Henrik Ekblad
7e3f5d2d54
Smart sleep
...
Add “Smart sleep” variants of all sleep methods that allows nodes to
receive buffered messages/commands from controller that was issued while
node was sleeping.. When calling the smartSleep() variant, the node
immediately sends a heartbeat mesage when waking up (informing
controller that node is awake). Before going back to sleep it waits
MY_SMART_SLEEP_WAIT_DURATION to process any incoming buffered messages
from the controller. NOTE: Controller must support this feature.
2015-11-28 22:45:52 +01:00
Henrik Ekblad
98554aba99
Merge pull request #268 from mfalkvidd/development
...
ClearEepromConfig: Fix spelling mistake
2015-11-28 13:21:21 +01:00
Henrik Ekblad
4790a151f5
Merge pull request #270 from mysensors/capabilities-embryo-and-mixed-fixes
...
Capabilities embryo, misc fixes
2015-11-28 13:20:24 +01:00
Henrik Ekblad
f8bdc3f55f
Include missing MyCapabilities.h
2015-11-28 12:20:56 +01:00
Henrik Ekblad
230d698bfd
Capabilities embryo, misc fixes
...
Call sketch setup() before presentation()
Bugfix in RFIDLockSensor
Disable remote reset option
Topic comparison bugix MQTT gateway
2015-11-28 12:03:43 +01:00
Mikael Falkvidd git@mjo.se
5f16b2209b
ClearEepromConfig: Fix spelling mistake
...
I agree to CLA
2015-11-27 22:24:16 +01:00
Patrick Fallberg
2041820b16
Merge pull request #267 from fallberg/sign-fix
...
Removed requirement for payload data for signed messages
2015-11-27 19:00:32 +01:00
Patrick Fallberg
8280479724
Removed requirement for payload data for signed messages
2015-11-27 13:53:10 +01:00
Henrik Ekblad
367dee18b0
Merge pull request #266 from mysensors/rs485-de-pin-management
...
DE-pin management for RS485 transport layer
2015-11-25 20:53:26 +01:00
Henrik Ekblad
7f360062dc
DE-pin management for RS485 transport layer
2015-11-25 20:05:09 +01:00
Henrik Ekblad
8e2c8cb420
Merge pull request #264 from soward/development
...
esp8266gateway crashing when receiving I_CONFIG message from new node…
2015-11-24 10:59:12 +01:00
Jps
8ff68f0bbe
esp8266gateway crashing when receiving I_CONFIG message from new node due to attempt to dereference the NULL return of MyMessage::getString()
2015-11-23 17:02:17 -05:00
Henrik Ekblad
c7814878f2
Merge pull request #263 from ToniA/development
...
HeatpumpIR library: Daikin air conditioner support
2015-11-23 19:24:23 +01:00
ToniA
cefc79dad2
Daikin air conditioner support
2015-11-23 18:50:23 +02:00
Henrik Ekblad
bbc6c8b531
Merge pull request #261 from windkh/development
...
Added weather station sensor example which is a merge between the two…
2015-11-22 20:41:19 +01:00
Henrik Ekblad
ff61bc0c5b
Merge pull request #262 from mysensors/fix-pa-level-bug
...
Fix RF24 PALevel not set correctly
2015-11-22 20:40:28 +01:00
windkh
94f441360b
Pressure is not rounded anymore: value is divided by 100.0 instead of 100.
2015-11-22 20:30:41 +01:00
Henrik Ekblad
0ab8431076
Fix RF24 PALevel not set correctly
2015-11-22 19:26:26 +01:00
windkh
60645f04f1
Added weather station sensor example which is a merge between the two examples
...
http://www.mysensors.org/build/humidity and http://www.mysensors.org/build/pressure
In addition to that the current weather situation is transmitted.
Right now the temperature values of both sensors are transmitted to the gateway. This is a bit redundant, but maybe useful when
mounting one the sensor (e.g. BMP) inside the building and the other one (DHT) outside of the building.
2015-11-22 14:08:42 +01:00
Patrick Fallberg
fd048ebdfb
Merge pull request #259 from fallberg/sign-fix
...
Fixed bug in repeaters when forwarding signed messages
2015-11-21 10:47:07 +01:00
Patrick Fallberg
f6e018f5e3
Fixed bug in repeaters when forwarding signed messages
...
For repeated messages, sign flag must not be touched.
2015-11-19 09:28:36 +01:00
Henrik Ekblad
e9f6a3ec41
Merge pull request #257 from Bekkie/patch-1
...
Update MyMessage.h
2015-11-19 09:02:43 +01:00
Henrik Ekblad
cc244e9338
Merge pull request #253 from fallberg/private
...
Added support for private configuration data
2015-11-19 08:59:34 +01:00
Patrick Fallberg
881abf1ec2
Merge pull request #258 from mysensors/fallberg-patch-1
...
Update README.md
2015-11-19 08:46:56 +01:00
Patrick Fallberg
a7e4d5bfd5
Update README.md
...
Updated to show status if all nightly builds.
2015-11-19 08:08:38 +01:00
Bart
f8d4000ed5
Update MyMessage.h
...
Add V_IR_RECORD message type for record and playback of IR codes
2015-11-18 22:58:28 +01:00
Henrik Ekblad
f3b291f2e9
Merge pull request #254 from mysensors/internal-messages-to-gw
...
Handle internal messages sent from controller to gateway
2015-11-18 21:39:29 +01:00
Henrik Ekblad
2cdcb95499
Handle internal messages sent from controller to gateway
...
Reduce memory footprint form W5100 gateway
2015-11-18 19:53:33 +01:00
Patrick Fallberg
cec516bc7e
Added support for private configuration data
...
libraries/MySensors/core/MyPrivateConfig.h.sample contain an example for
how private configuration data can be organized.
Rename that file to MyPrivateConfig.h and place it in the same folder
as the sketch you want to build and include it in order to add private
settings that you for various reasons do not want to store in git:
Make sure to place this include before
All MyPrivateConfig.h files are ignored by git.
2015-11-17 14:04:55 +01:00
Thomas Mørch
477929177f
Merge pull request #252 from fallberg/ota-fix
...
Activated OTA in SensebenderMicro example by default
2015-11-17 08:49:23 +01:00
Patrick Fallberg
7cacb7d4fe
Activated OTA in SensebenderMicro example by default
2015-11-16 22:14:26 +01:00
Henrik Ekblad
1df056b43e
Merge pull request #251 from mysensors/mqtt-repeater-mode-fix
...
Enable repeater mode for MQTT gateway when radio is attached.
2015-11-14 22:37:04 +01:00
Henrik Ekblad
a6a86ba1dd
Enable repeater mode for MQTT gateway when radio is attached.
2015-11-14 20:42:35 +01:00
Henrik Ekblad
0b4f6950c7
NodeJS controller example moved to separate repository
2015-11-12 22:54:32 +01:00
Henrik Ekblad
2719e08c2d
Merge pull request #250 from milvert/development
...
Remove include MyHw from MyHw.h
2015-11-12 18:16:45 +01:00
sm2810
59f8876870
Remove include MyHw from MyHw.h
2015-11-12 13:28:46 +01:00
Henrik Ekblad
49440c1efe
Merge pull request #249 from mysensors/MyMessage-getCommand
...
Add MyMessage:getCommand()
2015-11-12 07:18:01 +01:00
Henrik Ekblad
3ca69c422c
Merge pull request #248 from mysensors/RFM69-init-failure-detection
...
Detect if initialization fails for RFM69 radio
2015-11-12 00:31:01 +01:00
Henrik Ekblad
e1e26d5676
Add MyMessage:getCommand()
2015-11-11 23:54:12 +01:00
Henrik Ekblad
10a971fa90
Detect if initialization fails for RFM69 radio
...
Correct problem with define HW-variant
Clean up GatewayESP8266 comments
Change the debug message at startup (include version)
2015-11-11 23:33:46 +01:00